COD BOD TSS

Our range of products include online cod bod analyzers, cod bod tss ph analyzer, bod cod tss ph analyzer online, cod bod analyzer, online cod bod tss ph analyzer and online bod analyzer.

Online COD BOD Analyzers

Online COD BOD Analyzers
  • Online COD BOD Analyzers
  • Online COD BOD Analyzers
  • Online COD BOD Analyzers
  • Online COD BOD Analyzers
  • Online COD BOD Analyzers
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandTrios
MaterialTitanium
Automation TypeAutomatic
Range0-2000 mg/L
Working PrincipleAttenuation,Transmission
Accuracy0.2%
Protection TypeIP68 NEMA 6P
Ambient Temperature10 Deg C to 35 Deg C 50,95 Deg F
Measurement TechnologyLight Source: 2 LED(254nm,530nm)
Turbidity Compensationat 530 nm
T100 Response Time4s
System CompatibilityModbus RTU
Sample Temperature2 to 40 DegreeC I ~+36 DegreeF to +104 DegreeF

Long-lasting and energy-efficient UV-LED technology and a robust design are the core features of LISA UV. Like all TriOS sensors LISA uses the unique nanocoated windows combined with compressed air flushing to achieve long operating times without cleaning.

Benefits

  • Without sampling and preparation of test samples
  • Real-time sensor
  • Without reagents
  • Optical window with nano coating
  • LED technology
Request
Callback
Yes! I am Interested

COD BOD TSS PH Analyzer

COD BOD TSS PH Analyzer
  • COD BOD TSS PH Analyzer
  • COD BOD TSS PH Analyzer
  • COD BOD TSS PH Analyzer
  • COD BOD TSS PH Analyzer
  • COD BOD TSS PH Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandTriOS
MaterialTitanium
Automation TypeAutomatic
Gross Weight1.6 kg
Range0-2000 mg/L
Working PrincipleAttenuation,Transmission
Accuracy0.2%
Measurement TechnologyLight Source: 2 LED(254nm,530nm)
Optical path1mm,2mm,5mm,10mm,50mm
Turbidity Compensationat 530 nm
Power Consumption:<- 1W
Sample Temperature: 2 to 40 DegreeC I ~+36 DegreeF to +104 DegreeF
Storage Temperature-20 to 80 DegreeC I ~- 4 DegreeF to +176 DegreeF
Ambient Temperature2 to 40 DegreeC I ~+36 DegreeF to +104 DegreeF
Probe ratemin. 5ml/min
Max Pressure30 bar with SubConn ~ 435 psig
System CompatibilityModbus RTU or Analog Out(4 to 20 mA)
Ambient Temperature10 Deg C to 35 Deg C 50,95 Deg F
Protection TypeIP68 NEMA 6P

Long-lasting and energy-efficient UV-LED technology and a robust design are the core features of LISA UV. Like all TriOS sensors LISA uses the unique nanocoated windows combined with compressed air flushing to achieve long operating times without cleaning.The optical path length can be adapted to the application at any time by various lens sockets. An automatic turbidity compensation is carried out by a second measuring channel.Through application-specific correlation LISA UV can be con figured for direct output of BODeq, CODeq, TOCeq. A direct output of UVT254 is also possible.
Request
Callback
Yes! I am Interested

BOD COD TSS Ph Analyzer Online

BOD COD TSS Ph Analyzer Online
  • BOD COD TSS Ph Analyzer Online
  • BOD COD TSS Ph Analyzer Online
  • BOD COD TSS Ph Analyzer Online
  • BOD COD TSS Ph Analyzer Online
  • BOD COD TSS Ph Analyzer Online
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandTrios
MaterialTitanium
Automation TypeAutomatic
Range0-2000 mg/L
Accuracy0.2%
Measurement PrincipleAttenuation,Transmission
Protection TypeIP68 NEMA 6P
Ambient Temperature10 Deg C to 35 Deg C 50,95 Deg F
Measurement TechnologyLight Source: 2 LED(254nm,530nm)
Turbidity Compensationat 530 nm
T100 Response Time4s
System CompatibilityModbus RTU
Sample Temperature2 to 40 DegreeC I ~+36 DegreeF to +104 DegreeF

Benefits

  • Without sampling and preparation of test samples
  • Real-time sensor
  • Without reagents
  • Optical window with nano coating
  • LED technology

Long-lasting and energy-efficient UV-LED technology and a robust design are the core features of LISA UV. Like all TriOS sensors LISA uses the unique nanocoated windows combined with compressed air flushing to achieve long operating times without cleaning.

Request
Callback
Yes! I am Interested

COD Bod Analyzer

COD Bod Analyzer
  • COD Bod Analyzer
  • COD Bod Analyzer
  • COD Bod Analyzer
  • COD Bod Analyzer
  • COD Bod Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandTriOS
Usage/ApplicationIndustrial
Measurement TechnologyLight Source: 2 LED(254nm,530nm)
DetectorPhoto diode + Filter
Optical Path1mm,2mm,5mm,10mm,50mm
Turbidity Compensationat 530 nm
Data Logger~2 MB
T100 Response Time4s
System CompatibilityModbus RTU
Power Consumption<- 1W
Housing MaterialStainless Steel (1.4571/1.4404) or Titanium (3.7035)
Digital InterfaceEthernet (TCP/IP) RS-232 or RS-485 (Modbus RTU,Trios)
Sample Temperature2 to 40 DegreeC
Storage Temperature-20 to 80 DegreeC

Long-lasting and energy-efficient UV-LED technology and a robust design are the core features of LISA UV. Like all TriOS sensors LISA uses the unique nanocoated windows combined with compressed air flushing to achieve long operating times without cleaning.

Through application-specific correlation LISA UV can be con[1]figured for direct output of BODeq, CODeq, TOCeq. A direct output of UVT254 is also possible.

Through application-specific correlation LISA UV can be con[1]figured for direct output of BODeq, CODeq, TOCeq. A direct output of UVT254 is also possible.

Applications 

 

  • Sewage treatment plants 
  • Environmental monitoring
  • Drinking water
  • Monitoring of UV-disinfection systems
Request
Callback
Yes! I am Interested

Online COD BOD TSS PH Analyzer

Online COD BOD TSS PH Analyzer
  • Online COD BOD TSS PH Analyzer
  • Online COD BOD TSS PH Analyzer
  • Online COD BOD TSS PH Analyzer
  • Online COD BOD TSS PH Analyzer
  • Online COD BOD TSS PH Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandTRIOS
ShapeTitanium
Automation TypeAutomatic
Range0-2000 mg/L
Accuracy0.2%
Measurement PrincipleAttenuation, Transmission
Measurement TechnologyLight Source: 2 LED(254nm,530nm)
DetectorPhoto diode + Filter
Probe ratemin. 5ml/min
Max Pressure30 bar with SubConn ~ 435 psig
Max Pressure3 Bar with Fixed Cable ~ 43.5 psig
Max Pressure1 Bar, 2....4 L/min ~ 14.5 psig, 0.5 to 1 gpm
System CompatibilityModbus RTU or Analog Out (4 to 20 mA)

Long-lasting and energy-efficient UV-LED technology and a robust design are the core features of LISA UV. Like all TriOS sensors LISA uses the unique nanocoated windows combined with compressed air flushing to achieve long operating times without cleaning.

Applications 

  • Sewage treatment plants 
  • Environmental monitoring
  • Drinking water
  • Monitoring of UV-disinfection systems
Request
Callback
Yes! I am Interested

Online BOD Analyzer

Online BOD Analyzer
  • Online BOD Analyzer
  • Online BOD Analyzer
  • Online BOD Analyzer
  • Online BOD Analyzer
  • Online BOD Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandLAR
Measurement MethodContinuous 2-stream respiration measurement
Bacteria CultureOriginal Activated Sludge
Measurement RangeBOD: 1 - 50 mg/l, 1 - 200,000 mg/l ASR: 0 - 5 mg/l/min
Response Timemin. 3 - 4 minutes (application dependent)
HousingIP 54
Inflow and Outflow30 mm ID tube or threaded, 32 mm OD or as specified
Power Supply230 / 115 V~, 50 / 60 Hz, 100 VA
Analogue Output0/4-20 mA
Serial InterfaceRS 232, Combined alarms, Life-Zero, USB 2.0
Remote ControlThrough TCP/IP Protocol (Internet)

LAR’s BioMonitor is an online BOD analyzer for the determination of biochemical oxygen demand (BOD), respiration and toxicity in waste water. Using BioMonitor, operators can control their waste water treatment plant in an optimal way.
For safe operation in hazardous areas, there are different protection housings available:
IP54 (Standard)
Request
Callback
Yes! I am Interested

Biochemical Oxygen Demand

Biochemical Oxygen Demand
  • Biochemical Oxygen Demand
  • Biochemical Oxygen Demand
  • Biochemical Oxygen Demand
  • Biochemical Oxygen Demand
  • Biochemical Oxygen Demand
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Measurement MethodContinuous 2-stream respiration measurement
Bacteria CultureOriginal Activated Sludge
Measurement RangeBOD: 1 - 50 mg/l, 1 - 200,000 mg/l ASR: 0 - 5 mg/l/min
Response Timemin. 3 - 4 minutes (application dependent)
HousingIP 54
Inflow and Outflow30 mm ID tube or threaded, 32 mm OD or as specified
Power Supply230 / 115 V~, 50 / 60 Hz, 100 VA
Analogue Output0/4-20 mA
Serial InterfaceRS 232, Combined alarms, Life-Zero, USB 2.0
Remote ControlThrough TCP/IP Protocol (Internet)

LAR’s BioMonitor is an online BOD analyzer for the determination of biochemical oxygen demand (BOD), respiration and toxicity in waste water. Using BioMonitor, operators can control their waste water treatment plant in an optimal way.
Using analyzer options, the measurement system is adaptable for every measurement challenge.
FlowSampler
Request
Callback
Yes! I am Interested

Bod Analyzer

Bod Analyzer
  • Bod Analyzer
  • Bod Analyzer
  • Bod Analyzer
  • Bod Analyzer
  • Bod Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Measurement MethodContinuous 2-stream respiration measurement
Bacteria CultureOriginal Activated Sludge
Measurement RangeBOD: 1 - 50 mg/l, 1 - 200,000 mg/l ASR: 0 - 5 mg/l/min
Response Timemin. 3 - 4 minutes (application dependent)
HousingIP 54
Inflow and Outflow30 mm ID tube or threaded, 32 mm OD or as specified
Power Supply230 / 115 V~, 50 / 60 Hz, 100 VA
Analogue Output0/4-20 mA
Serial InterfaceRS 232, Combined alarms, Life-Zero, USB 2.0
Remote ControlThrough TCP/IP Protocol (Internet)

LAR’s BioMonitor is an online BOD analyzer for the determination of biochemical oxygen demand (BOD), respiration and toxicity in waste water. Using BioMonitor, operators can control their waste water treatment plant in an optimal way.
LAR’s biological oxygen demand analyzer is suitable for optimal waste water treatment plant controlling:
Environmental protectionBOD monitoringWWTP control
Request
Callback
Yes! I am Interested

BOD COD Sensor

BOD COD Sensor
  • BOD COD Sensor
  • BOD COD Sensor
  • BOD COD Sensor
  • BOD COD Sensor
  • BOD COD Sensor
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Measurement PrincipleAttenuation,Transmission
Range0-2000 mg/L
Measurement TechnologyLight Source: 2 LED(254nm,530nm)
DetectorPhoto diode + Filter
Turbidity Compensationat 530 nm
Optical path: 1mm,2mm,5mm,10mm,50mm
T100 Response Time4s
System CompatibilityModbus RTU
Power Consumption<- 1W
Sample Temperature2 to 40 DegreeC I ~+36 DegreeF to +104 DegreeF
Storage Temperature-20 to 80 DegreeC I ~- 4 DegreeF to +176 DegreeF

Long-lasting and energy-efficient UV-LED technology and a robust design are the core features of LISA UV. Like all TriOS sensors LISA uses the unique nanocoated windows combined with compressed air flushing to achieve long operating times without cleaning.
The optical path length can be adapted to the application at any time by various lens sockets. An automatic turbidity compensation is carried out by a second measuring channel.

 

Request