Product Details:
Measuring Range | 0-20 ppm,0-200% Saturation |
Application | Industrial |
Brand | Potence |
Detection Principle | luminescent quenching |
Response Time | 90% value in less than 60 seconds |
Operating Temperature | - 5 to 50 Degree C |
Accuracy | +- 0.5 % |
Measurement Principle | Luminescent optical technology |
Output Signal | 4-20 mA |
Enclosure Mounting | Wall, Panel |
Display | Backlit LCD Screen 4*20 Characters ; 5 Directional Keys |
Operating Conditions | -20 to 55 DegreeC |
Memory | Battery Back up |
Analog Output Signal | 2 Nos. ; 0 / 4-20 mA Isolated ; Max. Load 500 Ohms. |
Body Material | PVC Or SS Body |
Wetted, Body Material | SS (316L) / Titanium Body |
Sensor Cable | Standard 15 Meter |
Controller Type | P, PI and ON/OFF Controller |
Enclosure | IP 65 |
Working Temp | 0 to 50 DegreeC |
Power Requirements | 110 VAC / 230 VAC ; +- 10% ; 50 / 60 Hz |
Calibration Methods | 2 Point Calibration |
Measurement Range | 0.00 to 20.00 mg/l or 0.00 to 20.00 ppm or 0.0 to 200 % |
Storage Conditions | -20 to 65 DegreeC |
Measurement | : 2 Nos. ; Digital Sensor Inputs |
Digital Inputs | 2 Nos. ; For Pulse Input or Switching Input |
Relays | 3 Nos. ; Electromechanical SPST ; 6 A ; 250 VAC Max. |
Max. Pressure | 5 Bar |
Resolution | 0.01 mg/l or ppm |
Communication | Modbus RS 485 |
Digital Outputs | 2 Nos. ; Dry Contact Potential Free ; 12 V ; 200 mA |
Product Details:
Response Time | T90 < 40 Seconds |
Accuracy | + /- 0.1 ppm below 1 ppm : + /- 0.2 ppm above 1 ppm + /- 1% 0f reading |
Sensor Cable | 6 mtr. (optional cable length available up to 100 Meters) |
Resolution | : 0.1 ppm |
Salinity Compensation | Provided |
Input Power | 24VDC |
Wetted Material | PVC or SS body |
Connections | 1"NPT(M) front and back fittings |
Measurement Range | 0-20 ppm, 0-200% Saturation |
· Affordable as you do not have to rely on any specific controllers.
· 4-20mA output from sensor enables seamless connectivity to field transmitters or PLC/DCS.
· No electrolyte solution to replenish.
· Replaceable sensor cap.
· No calibration or replacement sensor cap for at least 1 year in most applications.
· Saltwater compensation.
· Sample flow not necessary for measurement accuracy.
· The sensor come with a choice of PVC body or SS 316 body version.
Sensor cable length up to 100 meters allow flexibility in the field.Product Details:
Response Time | T90 < 40 Seconds |
Accuracy | + /- 0.1 ppm below 1 ppm : + /- 0.2 ppm above 1 ppm + /- 1% 0f reading |
Measurement Range | 0-20 ppm, 0-200% Saturation |
Connections | 1"NPT(M) front and back fittings |
Resolution | 0.1 ppm |
Sensor Cable | 6 mtr. (optional cable length available up to 100 Meters) |
Wetted Material | PVC or SS body |
Salinity Compensation | Provided |
Input Power | 24VDC |
Potence Controls Optical Dissolved Oxygen sensors measure Dissolved Oxygen with great accuracy in waste water plants. They can connect to any existing measurement systems that accept a 4-20 mA input. This feature reduces the loop cost drastically as you can use any off the shelf Indicator and configure to measure Dissolved Oxygen.
Product Details:
Measuring range | 0 to 1000 ug/l O2 display up to 20000 ug/l separated in 3 measuring ranges |
Detection limit | 0.2 ug/l |
Resolution | 0.01 ug/l, adjustable |
Sample Pressure | 0 to 8 bar pressure peaks up to 16 bar |
Sample temperature | 0 to 60 DegreeC automatically compensated |
Interface | USB 2.0, optional Touch Memory (1-wire) |
Measurement error | < 1 % related to the measured value or minimum +- 0.5 ug/l |
Response time | t 90 < 8 s |
Calibration | manual and automatic calibration with self test, possible in three areas |
Data logger | 2000 data sets in a continuous data logger |
Product Details:
Detection limit | 0.2 ug/l |
Resolution | 0.01 ug/l, adjustable |
Response time | t 90 < 8 s |
Calibration | manual and automatic calibration with self test, possible in three areas |
Sample Pressure | 0 to 8 bar pressure peaks up to 16 bar |
Measuring range | 0 to 1000 ug/l O2 display up to 20000 ug/l separated in 3 measuring ranges |
Measurement error | < 1 % related to the measured value or minimum +- 0.5 ug/l |
Data logger | 2000 data sets in a continuous data logger |
Sample temperature | 0 to 60 DegreeC automatically compensated |
Interface | USB 2.0, optional Touch Memory (1-wire) |
Product Details:
Resolution | 0.1 ppm |
Salinity Compensation | Provided |
Sensor Cable | 6 mtr. (optional cable length available up to 100 Meters) |
Connections | 1"NPT(M) front and back fittings |
Wetted Material | PVC or SS body |
Measurement Range | 0-20 ppm, 0-200% Saturation |
Accuracy | + /- 0.1 ppm below 1 ppm : + /- 0.2 ppm above 1 ppm + /- 1% 0f reading |
Response Time | T90 < 40 Seconds |
Input Power | 24VDC |
Potence Controls Optical Dissolved Oxygen sensors measure Dissolved Oxygen with great accuracy in waste water plants.They can connect to any existing measurement systems that accept a 4-20 mA input. This feature reduces the loop cost drastically as you can use any off the shelf Indicator and configure to measure Dissolved Oxygen.
· Affordable as you do not have to rely on any specific controllers.
· 4-20mA output from sensor enables seamless connectivity to field transmitters or PLC/DCS.
· No electrolyte solution to replenish.
· Replaceable sensor cap.
· No calibration or replacement sensor cap for at least 1 year in most applications.
· Saltwater compensation.
· Sample flow not necessary for measurement accuracy.
· The sensor come with a choice of PVC body or SS 316 body version.
Sensor cable length up to 100 meters allow flexibility in the fieldProduct Details:
Brand | Potence |
Controller Type | P, PI and ON/OFF Controller |
Calibration Methods | 2 Point Calibration |
Operating Conditions | : -20 to 55 DegreeC |
Storage Conditions | -20 to 65 DegreeC |
Relays | 3 Nos. ; Electromechanical SPST ; 6 A ; 250 VAC Max. |
Memory | Battery Back up |
Display | Backlit LCD Screen 4*20 Characters ; 5 Directional Keys |
Enclosure Mounting | Wall, Panel |
Measurement | 2 Nos. ; Digital Sensor Inputs |
Power Requirements | 110 VAC / 230 VAC ; +- 10% ; 50 / 60 Hz |
Analog Output Signal | 2 Nos. ; 0 / 4-20 mA Isolated ; Max. Load 500 Ohms. |
Digital Inputs | : 2 Nos. ; For Pulse Input or Switching Input |
Digital Outputs | 2 Nos. ; Dry Contact Potential Free ; 12 V ; 200 mA |
Enclosure | IP 65 |
Potence Controls PCODOS Optical Dissolved Oxygen System is an excellent choice for an accurate measure in all situation with wide range of applications like Urban wastewater treatment; Industrial effluent treatment. Surface water monitoring , Sea water monitoring, Fish farming, Aquarium and Drinking water. The Optical Dissolved Oxygen sensor is based on Luminescent optical technology.
Without calibration requirements with ultra-low power technology, the Optical Dissolved Oxygen sensor meets the demands of field works. The “smart” Optical Dissolved Oxygen sensor stores calibration and history data within the sensor. This allows you a “plug and play” system.
· Optical Technology without calibration
· NO drift, Reduced Maintenance
· Stainless Steel (316L) or Titanium Body for Corrosive Applications
· Robust and Waterproof (IP 68)
· Controller with two digital sensor inputs.
· Backlit Display
· Password Protected Access
· Real time clock with Battery backup.
Product Details:
Response Time | t 90 < 8 s |
Data Logger | 2000 data sets in a continuous data logger |
Detection Limit | 0.2 ug/l |
Resolution | 0.01 ug/l, adjustable |
Interface | USB 2.0, optional Touch Memory (1-wire) |
Measurement | 0 to 1000 ug/l O2 display up to 20000 ug/l separated in 3 measuring ranges |
Measurement error | < 1 % related to the measured value or minimum +- 0.5 ug/l |
Sample Pressure | 0 to 8 bar pressure peaks up to 16 bar |
Calibration | manual and automatic calibration with self test, possible in three areas |
Sample temperature | 0 to 60 DegreeC automatically compensated |
Product Details:
Calibration | manual and automatic calibration with self test, possible in three areas |
Sample Pressure | 0 to 8 bar pressure peaks up to 16 bar |
Interface | USB 2.0, optional Touch Memory (1-wire) |
Resolution | 0.01 ug/l, adjustable |
Response time | t 90 < 8 s |
Detection limit | 0.2 ug/l |
Data logger | 2000 data sets in a continuous data logger |
Sample temperature | 0 to 60 DegreeC automatically compensated |
Measuring range | 0 to 1000 ug/l O2 display up to 20000 ug/l separated in 3 measuring ranges |
Measurement error | < 1 % related to the measured value or minimum +- 0.5 ug/l |
Product Details:
Brand | Potence |
Display Type | Seven Segment LED Display |
Analog Output | 4-20 mA ; Max. Load 600 Ohms |
Relays | Electromechanical SPDT ; 10A ; 115 / 230 VAC |
Enclosure | ABS |
Enclosure Dimension | H*W*D ( 48*96*75 ) mm |
Cut-Out | 44*92 mm |
Analog Output Function | Retransmission |
Wetted Material | PVC or SS body |
Relays Operational Mode | Control |
Enclosure Rating | IP 54 |
Power Requirements | 90- 270 VAC ; 50 / 60 Hz |
Analog Output Signal | 4-20 mA ; Max. Load 600 Ohms |
Potence Controls PCODOS Optical Dissolved Oxygen System is an excellent choice for an accurate measure in all situation with wide range of applications like Urban wastewater treatment; Industrial effluent treatment. Surface water monitoring , Sea water monitoring, Fish farming, Aquarium and Drinking water. The Optical Dissolved Oxygen sensor is based on Luminescent optical technology.
Without calibration requirements with ultra-low power technology, the Optical Dissolved Oxygen sensor meets the demands of field works. The “smart” Optical Dissolved Oxygen sensor stores calibration and history data within the sensor. This allows you a “plug and play” system.
Product Details:
Relays | Four Nos. Electromechanical SPDT |
Digital Communication | Modbus RS485 Output |
Enclosure Rating | IP65 |
mOUNTING | Wall or Panel or Pipe |
Analog Measurement | pH or ORP or Conductivity or Total Dissolved Solids |
Digital Measurement | DO or Turbidity or TSS or Chlorine |
Power Requirements | 100 to 270 VAC |
Analog Output Signals | Four Nos. 4 to 20mA isolated current outputs max 600ohms |
Product Details:
Measuring Range | 0 to 1000 ug/l O2 display up to 20000 ug/l separated in 3 measuring ranges |
Response Time | t 90 < 8 s |
Measurement error | < 1 % related to the measured value or minimum +- 0.5 ug/l |
Detection limit | 0.2 ug/l |
Sample temperature | 0 to 60 DegreeC automatically compensated |
Resolution | 0.01 ug/l, adjustable |
Calibration | manual and automatic calibration with self test, possible in three areas |
Sample Pressure | 0 to 8 bar pressure peaks up to 16 bar |
Interface | USB 2.0, optional Touch Memory (1-wire) |
Data logger | 2000 data sets in a continuous data logger |