Product Details:
Operating Voltage | 15 to 35 V DC |
Brand | Potence |
Material | 316 Stainless Steel, Blue Anodized Aluminium And Flame Proof Abs |
Protection | IP66 |
Mounting Type | Mounting Clamp With Wall Bracket Fixture |
Overall Length | 190 mm |
Weight | 0.9kg |
Diameter | 65 mm Max |
Product Details:
Display Type | 5 digit High Visibility LED |
Communications | RS232 / 485 |
Power Supply | 230/115 VAC |
Response Time | 90% of reading (T90) less than 2 seconds |
Model No | PM 700 |
Measurement Range | Auto-ranging from 0.01 to 100% O2 |
Display Resolution | 2 Decimal places (0.01 to 99.99%) |
Linearity | Better than +/- 0.1% O2 |
Repeatability | Better than +/- 0.02% O2 |
Pressure Compensation | Automatic compensation option |
Frequency | 50/60 Hz |
Ambient Temperature | -10 to + 45 Deg C |
Product Details:
Range | Autoranging from 0.1ppm to 100% |
Sample Inlet Pressure | 0.25 to 4 Barg |
Sample Flow Rate | Approximately 150cc/min |
Ambient Temperature | -5 to 50 DegreeC |
Communications | USB/RS232/RS485 |
Sample Connections | 1/8" OD compression fitting |
Response Time | 90% of step change within 5 seconds |
Repeatability | 0.2% of measured value |
Measuring Cell Type | Stabilised zirconia sensor |
Sample Temperature | -5 to 50 DegreeC |
Sample Humidity | 0-99% non-condensing |
Product Details:
Application | Industrial Use |
Automation Grade | Automatic |
Resolution | 0.1% O2 |
Material | MS |
Measurement Range | 0.1-100% O2 |
External Max | 550E O2 sensor |
Temperature Range | 0-50c (32-122F) |
Low Alarm Capabilities | 15% to 99% |
Product Details:
Usage/Application | Industrial |
Application | Industrial Use |
Automation Grade | Automatic |
Weight | 3 kg |
Dimension | 200W x 200H x 175D (mm) |
Installation | Wall mounted |
Ingress Protection | IP66, Nema 4X |
The EC96 Enables continuous monitoring of the oxygen level within confined rooms and work areas. Adjustable alarm contacts give early warning of changes in oxygen levels, allowing action to be taken. The EC96 O2 Deficiency Monitor transmits continuous oxygen concentration level to any control data acquistion System or programmable logic controller with 4-20mA
Additional Information:
Product Details:
Usage | Hospital |
Model | EC96 |
Warranty | 3 Years |
Frequency | 50/60Hz |
Weight | 3 kg |
Voltage | 230/115V |
Display Type | Analogue Meter |
Dimensions | 200W X200H X175D (mm) |
Ambient Temperature | 0 to 40 DegreeC |
The EC96 enables continuous monitoring of the oxygen level within confined rooms and work areas. Adjustable alarm contacts give early warning of changes in oxygen levels, allowing action to be taken. The EC96 O2 Deficiency Monitor transmits continuous oxygen concentration level to any control data acquisition system or programmable logic controller with 4-20mA input.
Supplied with 25 metres of cable as standard, allowing the cell to be mounted remotely, if required.
The EC96 incorporates diffusion type electrochemical sensor that does not require sample pumping making it easy to use and calibrate.
Description:
Product Details:
Spectral range | 640 mm |
Measuring ranges | 0 - 7.5 SI, 0 - 3000 SI |
Duct Diameter | 150 mm Triclamp version 1 thread version |
Electrical Saftey | CE |
Measured Values | Scattered light intensity dust concentration |
Measurement principles | Scattered light forward |
Product Details:
Measuring Range | 0 to 5 mg per m3 |
Response Time | 1s to 600s |
Electrical Safety | CE |
Measured Values | Scattered Light Intensity, Dust Concentration |
Measurement Principles | Scattered light forward |
Spectral Range | 640mm to 660mm |
Product Details:
Measured values | Transmittance, opacity, relative opacity, extinction, dust concentration (scattered light), dust con |
Transmittance | 100-90% / 100-0% |
Performance-tested measurands | Scattered light intensity, extinction |
Opacity | 0-10% / 0-100% |
Extinction | 0-0.045 / 0-2 |
Dust Concentration (Scattered Light) | 0-50 SI / 0-5 SI / 0-20 SI / 0 -100 SI / 0 - 200 SI |
Dust Concentration (Scattered Light) | 0-5 mg/m3 / 0-200 mg/m3 |
Dust Concentration (Transmittance) | 0-0.1 Ext / 0-0.05 Ext / 0-0.2 Ext / 0-0.5 Ext / 0 - 1 Ext |
Response Time | 1s - 600s |
Electrical Safety | CE |
Accuracy | +- 2 % |
Measurement principles | Transmittance measurement, scattered light forward |
Transmittance Measurement | 450nm - 700nm |
Scattered Light Forward | 640nm - 660nm |
Relative Opacity | 0-10% / 0-100% |
Dust Concentration (Transmittance) | 0-200 mg/m3 / 0-10000 mg/m3 |
Product Details:
Accuracy | +- 2 % |
Transmittance | 100-90% / 100-0% |
Opacity | 0-10% / 0-100% |
Measured values | Transmittance, opacity, relative opacity, extinction, dust concentration |
Spectral Range | 450nm - 700nm |
Relative Opacity | 0-10% / 01-00% |
Dust Concentration | 0-200 mg/m3 / 0-10000 mg/m3 |
Response Time | 1s - 600s Freely adjustable |
Electrical Safety | CE |
Performance-tested measurands | Dust Concentration |
Measurement principles | Transmittance measurement |
Extinction | 0-0.045 / 0-2 |
Product Details:
Accuracy | +- 2 % Of measuring range full scale |
Spectral Range | 640nm to 660nm |
Response Time | 0.1s to 600s Freely adjustable |
Measurement Principles | Scattered light forward |
Process Gas Humidity | Max. 40 g/m3 liquid water without water vapour |
Performance-tested measurands | Dust Concentration |
Dust Concentration | 0 to 5 mg/m3 or 0 to 500 mg/m3 |
Process Gas Velocity | 5 m/s to 30 m/s |
Measured values | Scattered light intensity, dust concentration (after gravimetric comparison measurement) |