Product Details:
Power Supply | 230/115 VAC |
Response Time | 90% of reading (T90) less than 2 seconds |
Frequency | 50/60 Hz |
Ambient Temperature | -10 to + 45 Deg C |
Model No | PM 700 |
Measurement Range | Auto-ranging from 0.01 to 100% O2 |
Display Resolution | 2 Decimal places (0.01 to 99.99%) |
Display Type | 5 digit High Visibility LED |
Linearity | Better than +/- 0.1% O2 |
Repeatability | Better than +/- 0.02% O2 |
Pressure Compensation | Automatic compensation option |
Communications | RS232 / 485 |
Product Details:
Range | Autoranging from 0.1ppm to 100% |
Response Time | 90% of step change within 5 seconds |
Repeatability | 0.2% of measured value |
Measuring Cell Type | Stabilised zirconia sensor |
Sample Inlet Pressure | 0.25 to 4 Barg |
Sample Flow Rate | Approximately 150cc/min |
Sample Temperature | -5 to 50 DegreeC |
Ambient Temperature | -5 to 50 DegreeC |
Sample Humidity | 0-99% non-condensing |
Sample Connections | 1/8" OD compression fitting |
Communications | USB/RS232/RS485 |
Product Details:
Application | Industrial Use |
Automation Grade | Automatic |
Resolution | 0.1% O2 |
Material | MS |
Measurement Range | 0.1-100% O2 |
Temperature Range | 0-50c (32-122F) |
Low Alarm Capabilities | 15% to 99% |
External Max | 550E O2 sensor |
Product Details:
Operating Voltage | 15 to 35 V DC |
Brand | Potence |
Protection | IP66 |
Material | 316 Stainless Steel, Blue Anodized Aluminium And Flame Proof Abs |
Mounting Type | Mounting Clamp With Wall Bracket Fixture |
Overall Length | 190 mm |
Diameter | 65 mm Max |
Weight | 0.9kg |
Product Details:
Usage/Application | Industrial |
Application | Industrial Use |
Automation Grade | Automatic |
Weight | 3 kg |
Dimension | 200W x 200H x 175D (mm) |
Ingress Protection | IP66, Nema 4X |
Installation | Wall mounted |
The EC96 Enables continuous monitoring of the oxygen level within confined rooms and work areas. Adjustable alarm contacts give early warning of changes in oxygen levels, allowing action to be taken. The EC96 O2 Deficiency Monitor transmits continuous oxygen concentration level to any control data acquistion System or programmable logic controller with 4-20mA
Additional Information:
Product Details:
Usage | Hospital |
Model | EC96 |
Warranty | 3 Years |
Ambient Temperature | 0 to 40 DegreeC |
Voltage | 230/115V |
Frequency | 50/60Hz |
Display Type | Analogue Meter |
Weight | 3 kg |
Dimensions | 200W X200H X175D (mm) |
The EC96 enables continuous monitoring of the oxygen level within confined rooms and work areas. Adjustable alarm contacts give early warning of changes in oxygen levels, allowing action to be taken. The EC96 O2 Deficiency Monitor transmits continuous oxygen concentration level to any control data acquisition system or programmable logic controller with 4-20mA input.
Supplied with 25 metres of cable as standard, allowing the cell to be mounted remotely, if required.
The EC96 incorporates diffusion type electrochemical sensor that does not require sample pumping making it easy to use and calibrate.
Description:
Product Details:
Measured Values | Scattered light intensity dust concentration |
Measurement principles | Scattered light forward |
Spectral range | 640 mm |
Measuring ranges | 0 - 7.5 SI, 0 - 3000 SI |
Duct Diameter | 150 mm Triclamp version 1 thread version |
Electrical Saftey | CE |
Product Details:
Measured Values | Scattered Light Intensity, Dust Concentration |
Measurement Principles | Scattered light forward |
Spectral Range | 640mm to 660mm |
Measuring Range | 0 to 5 mg per m3 |
Response Time | 1s to 600s |
Electrical Safety | CE |
Product Details:
Measured values | Transmittance, opacity, relative opacity, extinction, dust concentration (scattered light), dust con |
Performance-tested measurands | Scattered light intensity, extinction |
Measurement principles | Transmittance measurement, scattered light forward |
Transmittance Measurement | 450nm - 700nm |
Scattered Light Forward | 640nm - 660nm |
Transmittance | 100-90% / 100-0% |
Opacity | 0-10% / 0-100% |
Relative Opacity | 0-10% / 0-100% |
Extinction | 0-0.045 / 0-2 |
Dust Concentration (Transmittance) | 0-200 mg/m3 / 0-10000 mg/m3 |
Dust Concentration (Scattered Light) | 0-5 mg/m3 / 0-200 mg/m3 |
Dust Concentration (Scattered Light) | 0-50 SI / 0-5 SI / 0-20 SI / 0 -100 SI / 0 - 200 SI |
Dust Concentration (Transmittance) | 0-0.1 Ext / 0-0.05 Ext / 0-0.2 Ext / 0-0.5 Ext / 0 - 1 Ext |
Response Time | 1s - 600s |
Accuracy | +- 2 % |
Electrical Safety | CE |
Product Details:
Accuracy | +- 2 % |
Measured values | Transmittance, opacity, relative opacity, extinction, dust concentration |
Performance-tested measurands | Dust Concentration |
Measurement principles | Transmittance measurement |
Spectral Range | 450nm - 700nm |
Transmittance | 100-90% / 100-0% |
Opacity | 0-10% / 0-100% |
Relative Opacity | 0-10% / 01-00% |
Extinction | 0-0.045 / 0-2 |
Dust Concentration | 0-200 mg/m3 / 0-10000 mg/m3 |
Response Time | 1s - 600s Freely adjustable |
Electrical Safety | CE |
Product Details:
Accuracy | +- 2 % Of measuring range full scale |
Measured values | Scattered light intensity, dust concentration (after gravimetric comparison measurement) |
Performance-tested measurands | Dust Concentration |
Measurement Principles | Scattered light forward |
Spectral Range | 640nm to 660nm |
Dust Concentration | 0 to 5 mg/m3 or 0 to 500 mg/m3 |
Response Time | 0.1s to 600s Freely adjustable |
Process Gas Velocity | 5 m/s to 30 m/s |
Process Gas Humidity | Max. 40 g/m3 liquid water without water vapour |