Our product range includes a wide range of online ph transmitter, industrial ph transmitter, ph sensor orp redox sensor, ph orp transmitter controller, online orp transmitter and inline orp electrode.
Get Latest Price
| Measurement | pH/ORP or Conductivity or Total Dissolved Solids (TDS) (Freely selectable via software) |
| Display | Graphic LCD with Backlit display |
| Display Dimension | 60*30 mm |
| Power Requirements | 100 - 270 VAC +-10%, 50/60 Hz |
| Operating Conditions | Temperature : 0 - 65 DegreeC, RH - 0-95% Non-condensing |
| Storage Conditions | Temperature : 0 - 75 DegreeC |
| Analog Output Signal | Two Nos 4 to 20 mA isolated current outputs max 600 ohms |
| Analog Output Function | Retransmission |
| Relays | Four Nos. electromechanical SPDT ; 10A ;115/230 VAC |
| Relays Operational Mode | Control and Alarm |
| Digital Communication | Modbus RS 485 Output |
| Memory | Non Volatile |
| Test / Maintenance | Provides Analog Output Test Signals to confirm operation of connected devices and Test Relay Opera |
| Enclosure | Thermoset Plastic ; SS |
| Enclosure Dimension | H*W*D (144*144*132) mm |
| Conduit Entry / Nos. | 1/2" NPT; 6 Nos |
| Enclosure Rating | IP 65 |
| Mounting | Wall ; Pipe ; Panel |
Get Latest Price
| Measurement | pH/ORP or Conductivity or Total Dissolved Solids (TDS) (Freely selectable via software) |
| Display | Graphic LCD with Backlit display |
| Display Dimension | 60*30 mm |
| Power Requirements | 100 - 270 VAC +-10%, 50/60 Hz |
| Operating Conditions | Temperature : 0 - 65 DegreeC, RH - 0-95% Non-condensing |
| Storage Conditions | Temperature : 0 - 75 DegreeC |
| Analog Output Signal | Two Nos 4 to 20 mA isolated current outputs max 600 ohms |
| Analog Output Function | Retransmission |
| Relays | Two Nos. electromechanical SPDT ; 10A ;115/230 VAC |
| Relays Operational Mode | Control and Alarm |
| Digital Communication | Modbus RS 485 Output |
| Memory | Non Volatile |
| Calibration Methods | Refer Sensor Data details |
| Test / Maintenance | Provides Analog Output Test Signals to confirm operation of connected devices and Test Relay Opera |
| Enclosure | ABS |
| Enclosure Dimension | H*W*D (96*96*110) mm |
| Enclosure Rating | IP54 |
| Mounting | Panel |
Get Latest Price
| Model Name/Number | pH100P |
| Accuracy | +/- 0.1% of FS |
| Range | 0 to 14 |
| Temp.Compensation | Automatic / Manual |
| Memory | Non Volatile (EEPROM) |
| Output 1 | 4-20mA (Max. Load 600 Ohms) |
| Output 2 | 4-20mA (Max. Load 600 Ohms) |
| Relay A | 230 VAC, 5A, Potential Free contact, SPDT |
| Relay B | 230 VAC, 5A, Potential Free Contact, SPDT |
| Enclosure Material | ABS |
| Dimensions | 96*96*55 mm |
| Mounting | Panel |
Get Latest Price
| Calibration | 2 point |
| Resolution | 0.01pH |
| Ph Range | 0 to 14 |
| Accuracy | +/- 0.1% of FS |
| Temperature Compensation | Automatic / Manual |
| Memory | Non Volatile |
| Power Supply | 100-270 VAC, 50 Hz |
| Output 1 | 4-20mA (Max. Load 600 Ohms) |
| Output 2 | 4-20mA (Max. Load 600 Ohms) |
| Relay A | 230 VAC, 5A, Potential Free Contact SPDT |
| Relay B | 230 VAC, 5A, Potential Free Contact SPDT |
| Enclosure Material | ABS |
| Dimensions | 96*96*55 mm |
| Mounting | Panel |
Get Latest Price
| Measurement | pH/ORP or Conductivity or Total Dissolved Solids (TDS) (Freely selectable via software) |
| Display | Graphic LCD with Backlit display |
| Graphic LCD with Backlit display | 60*30 mm |
| Power Requirements | 100 - 270 VAC +-10%, 50/60 Hz |
| Operating Conditions | Temperature : 0 - 65 DegreeC, RH - 0-95% Non-condensing |
| Storage Conditions | Temperature : 0 - 75 DegreeC |
| Analog Output Signal | Two Nos 4 to 20 mA isolated current outputs max 600 ohms |
| Analog Output Function | Retransmission |
| Relays | Four Nos. electromechanical SPDT ; 10A ;115/230 VAC |
| Relays Operational Mode | Control and Alarm |
| Digital Communication | Modbus RS 485 Output |
| Memory | Non Volatile |
| Enclosure | Thermoset Plastic ; SS |
| Enclosure Dimension | H*W*D (144*144*132) mm |
| Enclosure Rating | IP 65 |
Get Latest Price
| Brand | Potence |
| Temp. Limit | 0-105 DegreeC |
| Pressure Limit | 0-100 psig 100 DegreeC (0-6.9 bar @ 100 DegreeC) |
| Accuracy | Limited to calibration Solution Accuracy ( + / - 20mV) |
| Measuring range | - 2000 mV to + 2000 mV |
| Wetted Material | Ryton body (glass filled), glass with platinum process electrode |
Get Latest Price
| Mounting | Panel |
| Measurement | pH/ORP or Conductivity or Total Dissolved Solids (TDS) (Freely selectable via software) |
| Display | Graphic LCD with Backlit display |
| Graphic LCD with Backlit display | 60*30 mm |
| Power Requirements | 100 - 270 VAC +-10%, 50/60 Hz |
| Operating Conditions | Temperature : 0 - 65 DegreeC, RH - 0-95% Non-condensing |
| Storage Conditions | Temperature : 0 - 75 DegreeC |
| Analog Output Signal | Two Nos 4 to 20 mA isolated current outputs max 600 ohms |
| Analog Output Function | Retransmission |
| Relays | Two Nos. electromechanical SPDT ; 10A ;115/230 VAC |
| Relays Operational Mode | Control and Alarm |
| Memory | Non Volatile |
| Calibration Methods | Refer Sensor Data Details |
| Test / Maintenance | Provides Analog Output Test Signals to confirm operation of connected devices and Test Relay Opera |
Get Latest Price
Get Latest Price
Get Latest Price
Get Latest Price
Get Latest Price
Get Latest Price
Get Latest Price
Get Latest Price
Get Latest Price
Get Latest Price
Get Latest Price
PRASHANT JETHABHAI THAKKAR (Director)
Potence Controls Pvt. Ltd.
G-416a, Kailas Industrial Complex, 90 Feet D.P. Road, Parksite Vikhroli West
Mumbai - 400079, Maharashtra, India