Product Details:
Brand | Potence |
Temp. Limit | 0-105 DegreeC |
Pressure Limit | 0-100 psig 100 DegreeC (0-6.9 bar @ 100 DegreeC) |
Accuracy | Limited to calibration Solution Accuracy ( + / - 20mV) |
Measuring range | - 2000 mV to + 2000 mV |
Wetted Material | Ryton body (glass filled), glass with platinum process electrode |
Product Details:
Measurement | pH/ORP or Conductivity or Total Dissolved Solids (TDS) (Freely selectable via software) |
Display | Graphic LCD with Backlit display |
Display Dimension | 60*30 mm |
Power Requirements | 100 - 270 VAC +-10%, 50/60 Hz |
Operating Conditions | Temperature : 0 - 65 DegreeC, RH - 0-95% Non-condensing |
Storage Conditions | Temperature : 0 - 75 DegreeC |
Analog Output Signal | Two Nos 4 to 20 mA isolated current outputs max 600 ohms |
Analog Output Function | Retransmission |
Relays | Four Nos. electromechanical SPDT ; 10A ;115/230 VAC |
Relays Operational Mode | Control and Alarm |
Digital Communication | Modbus RS 485 Output |
Memory | Non Volatile |
Test / Maintenance | Provides Analog Output Test Signals to confirm operation of connected devices and Test Relay Opera |
Enclosure | Thermoset Plastic ; SS |
Enclosure Dimension | H*W*D (144*144*132) mm |
Conduit Entry / Nos. | 1/2" NPT; 6 Nos |
Enclosure Rating | IP 65 |
Mounting | Wall ; Pipe ; Panel |
Product Details:
Measurement | pH/ORP or Conductivity or Total Dissolved Solids (TDS) (Freely selectable via software) |
Display | Graphic LCD with Backlit display |
Graphic LCD with Backlit display | 60*30 mm |
Power Requirements | 100 - 270 VAC +-10%, 50/60 Hz |
Operating Conditions | Temperature : 0 - 65 DegreeC, RH - 0-95% Non-condensing |
Storage Conditions | Temperature : 0 - 75 DegreeC |
Analog Output Signal | Two Nos 4 to 20 mA isolated current outputs max 600 ohms |
Analog Output Function | Retransmission |
Relays | Four Nos. electromechanical SPDT ; 10A ;115/230 VAC |
Relays Operational Mode | Control and Alarm |
Digital Communication | Modbus RS 485 Output |
Memory | Non Volatile |
Enclosure | Thermoset Plastic ; SS |
Enclosure Dimension | H*W*D (144*144*132) mm |
Enclosure Rating | IP 65 |
Product Details:
Model Name/Number | pH100P |
Accuracy | +/- 0.1% of FS |
Range | 0 to 14 |
Temp.Compensation | Automatic / Manual |
Memory | Non Volatile (EEPROM) |
Output 1 | 4-20mA (Max. Load 600 Ohms) |
Output 2 | 4-20mA (Max. Load 600 Ohms) |
Relay A | 230 VAC, 5A, Potential Free contact, SPDT |
Relay B | 230 VAC, 5A, Potential Free Contact, SPDT |
Enclosure Material | ABS |
Dimensions | 96*96*55 mm |
Mounting | Panel |
Product Details:
Calibration | 2 point |
Resolution | 0.01pH |
Ph Range | 0 to 14 |
Accuracy | +/- 0.1% of FS |
Temperature Compensation | Automatic / Manual |
Memory | Non Volatile |
Power Supply | 100-270 VAC, 50 Hz |
Output 1 | 4-20mA (Max. Load 600 Ohms) |
Output 2 | 4-20mA (Max. Load 600 Ohms) |
Relay A | 230 VAC, 5A, Potential Free Contact SPDT |
Relay B | 230 VAC, 5A, Potential Free Contact SPDT |
Enclosure Material | ABS |
Dimensions | 96*96*55 mm |
Mounting | Panel |
Product Details:
Measurement | pH/ORP or Conductivity or Total Dissolved Solids (TDS) (Freely selectable via software) |
Display | Graphic LCD with Backlit display |
Display Dimension | 60*30 mm |
Power Requirements | 100 - 270 VAC +-10%, 50/60 Hz |
Operating Conditions | Temperature : 0 - 65 DegreeC, RH - 0-95% Non-condensing |
Storage Conditions | Temperature : 0 - 75 DegreeC |
Analog Output Signal | Two Nos 4 to 20 mA isolated current outputs max 600 ohms |
Analog Output Function | Retransmission |
Relays | Two Nos. electromechanical SPDT ; 10A ;115/230 VAC |
Relays Operational Mode | Control and Alarm |
Digital Communication | Modbus RS 485 Output |
Memory | Non Volatile |
Calibration Methods | Refer Sensor Data details |
Test / Maintenance | Provides Analog Output Test Signals to confirm operation of connected devices and Test Relay Opera |
Enclosure | ABS |
Enclosure Dimension | H*W*D (96*96*110) mm |
Enclosure Rating | IP54 |
Mounting | Panel |
Product Details:
Mounting | Panel |
Measurement | pH/ORP or Conductivity or Total Dissolved Solids (TDS) (Freely selectable via software) |
Display | Graphic LCD with Backlit display |
Graphic LCD with Backlit display | 60*30 mm |
Power Requirements | 100 - 270 VAC +-10%, 50/60 Hz |
Operating Conditions | Temperature : 0 - 65 DegreeC, RH - 0-95% Non-condensing |
Storage Conditions | Temperature : 0 - 75 DegreeC |
Analog Output Signal | Two Nos 4 to 20 mA isolated current outputs max 600 ohms |
Analog Output Function | Retransmission |
Relays | Two Nos. electromechanical SPDT ; 10A ;115/230 VAC |
Relays Operational Mode | Control and Alarm |
Memory | Non Volatile |
Calibration Methods | Refer Sensor Data Details |
Test / Maintenance | Provides Analog Output Test Signals to confirm operation of connected devices and Test Relay Opera |