Product Details:
Resolution | 0.01 to 1 NTU-mg/L |
Accuracy | < +- 5% of the reading |
Measurement Range | Turbidity: 0 to 4000 NTU TSS : 0 to 4500 mg/L |
Measurement Principle | IR light method dispersed at 90 Degree (ISO 7027) |
Wetted Material | PVC Body |
Max. Refreshing Time | < 1 second |
Working Temp. Range | 0 to 50 DegreeC |
Max. Pressure | 5Bar |
Sensor Cable | Standard 7 Meter |
Potence Controls PCTUS Turbidity / TSS System is an excellent choice for a wide range of applications like Urban wastewater treatment : Sanitation network; Industrial effluent treatment;
Surface water monitoring and Drinking water.
Turbidity sensors are optical sensors. The sensor measurement principle is based on the IR light method dispersed at 90° (ISO 7027). The measurement is carried out in the Infrared range.
Product Details:
Measurement Principle | IR light method dispersed at 90 Degree (ISO 7027) |
Measurement Range | Turbidity: 0 to 4000 NTU TSS : 0 to 4500 mg/L |
Accuracy | < +- 5% of the reading |
Resolution | 0.01 to 1 NTU-mg/L |
Max. Refreshing Time | < 1 second |
Working Temp. Range | 0 to 50 DegreeC |
Sensor Cable | Standard 7 Meter |
Measurement | 2 Nos. ; Digital Sensor Inputs |
Operating Conditions | -20 to 55 DegreeC |
Storage Conditions | -20 to 65 DegreeC |
Analog Output Signal | 2 Nos. ; 0 / 4-20 mA Isolated ; Max. Load 500 Ohms. |
Relays | 3 Nos. ; Electromechanical SPST ; 6 A ; 250 VAC Max. |
Memory | Battery Back up |
Calibration Methods | 2 Point Calibration |
Enclosure | IP65 |
Potence Controls Optical Dissolved Oxygen sensors measure Dissolved Oxygen with great accuracy in waste water plants. They can connect to any existing measurement systems that accept a 4-20 mA input. This feature reduces the loop cost drastically as you can use any off the shelf Indicator and configure to measure Dissolved Oxygen.
• Affordable as you do not have to rely on any specific controllers.
• 4-20mA output from sensor enables seamless connectivity to field transmitters or PLC/DCS.
• No electrolyte solution to replenish.
• Replaceable sensor cap.
• No calibration or replacement sensor cap for at least 1 year in most applications.
• Saltwater compensation.
• Sample flow not necessary for measurement accuracy.
• The sensor come with a choice of PVC body or SS 316 body version.
• Sensor cable length up to 100 meters allow flexibility in the field.
Product Details:
Brand | Potence |
Measurement | 2 Nos. ; Digital Sensor Inputs |
Display | Backlit LCD Screen 4*20 Characters ; 5 Directional Keys |
Power Requirements | 110 VAC / 230 VAC ; +- 10% ; 50 / 60 Hz |
Operating Conditions | -20 to 55 DegreeC |
Storage Conditions | -20 to 65 DegreeC |
Analog Output Signal | 2 Nos. ; 0 / 4-20 mA Isolated ; Max. Load 500 Ohms. |
Relays | 3 Nos. ; Electromechanical SPST ; 6 A ; 250 VAC Max. |
Memory | Battery Back up |
Calibration Methods | 2 Point Calibration |
Enclosure Mounting | Wall, Panel |
Digital Outputs | 2 Nos. ; Dry Contact Potential Free ; 12 V ; 200 mA |
Digital Inputs | 2 Nos. ; For Pulse Input or Switching Input |