Potence Controls Pvt. Ltd.
Potence Controls Pvt. Ltd.
Vikhroli West, Mumbai, Maharashtra
GST No. 27AAGCP7095P1ZH
TrustSEAL Verified
Call 0804896923280% Response Rate
SEND EMAIL

Water Analyzers

Pioneers in the industry, we offer ph orp sensor, portable trace oxygen analyzer, optical oxygen analyzer, degassed acid conductivity analyzer, oil in water monitor and free chlorine sensor from India.

pH ORP Sensor

pH ORP Sensor
  • pH ORP Sensor
  • pH ORP Sensor
  • pH ORP Sensor
  • pH ORP Sensor
  • pH ORP Sensor
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandPotence
pH Range0 - 14 pH
Max. Flow Range0-6.6 ft/sec (0-2 m/sec)
Temp. Limit0-105 Degree C
ORP Range-2000mV to +2000mV
Pressure Limit0-100 psig @ 100 DegreeC (0-6.9 bar @100 DegreeC)
Country of OriginMade in India

Potence Controls PC Series combination pH / ORP sensors are designed for special applications. They can be mounted in a Flow through Tee / Chamber or Immersed in Tanks/ Vessels.
The reference cell is Double -Junction porous teflon design and comes with a built-in solution Ground owing to which the perfomrance of this sensors is enhanced. The body is made from chemically- resistant Ryton which is suitable for some of the most Harsh Applications.
The sensors are rated for 0-105°C, 100psig andcome with a standard 15 feet cable.
The sensors also comes with a choice of Temparature elements like Pt 100, Pt 1000, other elements available on request. 
These sensors can be connected to most of the different brands of Transmitters / Controllers.

PC series sensors Different Configuarations:
  • Dome shaped
  • High Purity
  • Detachable Cable
  • Insertion Type with Retractable options.
Request
Callback
Yes! I am Interested

Portable Trace Oxygen Analyzer

Portable Trace Oxygen Analyzer
  • Portable Trace Oxygen Analyzer
  • Portable Trace Oxygen Analyzer
  • Portable Trace Oxygen Analyzer
  • Portable Trace Oxygen Analyzer
  • Portable Trace Oxygen Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Model Name/NumberDigox 6.1 KS stationary
Weight8.0 kg
Rated Voltage100-240 VAC
Frequency50/60 Hz
Ambient Temperature0-40 DegreeC
IP RatingIP 65
Size580 x 335 x 140 mm

Accuracy and safety in the process

The Digox 6.1 measures traces of dissolved oxygen in process water and high-purity water. Both, stationary and portable instruments, are designed for continuous operation in sampling systems for water-steam cycles. Data interfaces, analog signals, alarms and contacts offer a variety of options to integrate the Digox 6.1 into a process control system. The rugged design of the Thiedig sensor with its automatic calibration allows for a nearly maintenance-free continuous operation. The calibration can be performed at any time during the measuring operation or activated in programmable time intervals. Hence, a safe and reliable measurement is always guaranteed.


Request
Callback
Yes! I am Interested

Optical Oxygen Analyzer

Optical Oxygen Analyzer
  • Optical Oxygen Analyzer
  • Optical Oxygen Analyzer
  • Optical Oxygen Analyzer
  • Optical Oxygen Analyzer
  • Optical Oxygen Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandDr. Thiedig
Weight5.2 kg
Measuring Range0 to 2000 microg/l
Analog Output4 to 20 mA
AlarmSwitching Contacts
Dimensions850 x 200 x 180 mm
Voltage24 VDC
Power Consumption15 Watt

The Digox Optical is a state-of-the-art oxygen measuring device based on the principle of the dynamic fluorescence Quenching. The device uses neither a membrane nor an electrolyte. Also, the principle is independent of the CO concentration of the sample and 2 the sample flow. Additional features are a low maintenance and a longer uptime. 

Features:

  • Simultaneous measurement of dissolved oxygen, temperature and sample flow
  • Easy installation, low maintenance and a long period of operation
  • Analogue and digital outputs Profibus communication (option)
  • Integrated Flowmeter

Other Details

The Digox Optical is a state-of-the-art oxygen measuring device based on the principle of the dynamic fluorescence Quenching. The device uses neither a membrane nor an electrolyte. Also, the principle is independent of the CO concentration of the sample and 2 the sample flow. Additional features are a low maintenance and a longer uptime. A blue light source excites a luminophore in the sensor cap. Electrons of the luminophore absorb the energy of the incident blue light and are transferred to a higher energy level. Within a very short time (Microseconds) the electrons revert to lower energy levels and the energy is released in form of a red light. Oxygen is able to take over the energy of the excited electrons of the luminophore and the intensity of the emitted red light is a function of the oxygen concentration in the sample. Also, the presence of oxygen molecules accelerates the process of the electrons for leaving the higher energy level. The intensity of the emitted red light and the fading time of the red light are a function of the oxygen concentration in the sample. The resulting life period of the emitted red light directly indicates the oxygen concentration in the sample.
Request
Callback
Yes! I am Interested

Degassed Acid Conductivity Analyzer

Degassed Acid Conductivity Analyzer
  • Degassed Acid Conductivity Analyzer
  • Degassed Acid Conductivity Analyzer
  • Degassed Acid Conductivity Analyzer
  • Degassed Acid Conductivity Analyzer
  • Degassed Acid Conductivity Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

ApplicationIndustrial Use
Usage/ApplicationIndustrial Use
BrandDr. Thiedig
Weight27.5 kg
Dimension850 x 570 x 210 mm (HxWxD)
Measuring range0-1000 microS/cm
DisplayGraphic display
Analog output4 to 20 mA
Power Supply90 to 264 VAC

The conductivity in water-steam cycle in power plants is an important measurement.

Other Details:
  • No heating up, therefore no gas emissions of other volatile acids
  • No inert gas required, air-conditioning by means of a molecular sieve
  • Interpolation of measuring results to actual CO2 content
  • Automatic shut down of the DAC reactor following the fall below the acceptable limit of 0.2 μS cm-1 (VGB-guideline)
  • Short response times
Request
Callback
Yes! I am Interested

Oil In Water Monitor

Oil In Water Monitor
  • Oil In Water Monitor
  • Oil In Water Monitor
  • Oil In Water Monitor
  • Oil In Water Monitor
  • Oil In Water Monitor
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Usage/ApplicationIndustrial Use
BrandTurner Designs
Model Name/NumberTD-120
Sample Temperature32-122 DegreeF (0-50 DegreeC)-for higher temperatures consult factory
Ambient Operating Temperature32-131 DegreeF (0-55 DegreeC)
Operational PrincipleUV Fluorescence
Calibration Stability+/- 10% over 12 months or better
Alarms4x dry contact user configurable alarms: Early,High,System,Cell Condition,High Temperature
Response Time3 seconds default (user adjustable,down to 0.5 seconds),continuous reading
Sample Inlet10-100 psig (69-690 kPag)-for higher pressures consult factory
HydrocarbonsDiesel,fuel oil,crude oil,gasoline,jet fuel,lubricating oils,phenol,heat transfer fluids
Detection RangeLow ppb -6000 ppm
Communications4-20 mA isolated,selectable loop or instrument powered Optional: HART

Turner Designs Hydrocarbon Instruments has been theworld leader in oil in water monitoring for more than 20years. The TD-120 Oil in Water Monitor was developedbased on our extensive real-world experience and offersUV fluorescence technology with industry leading features.The TD-120 is available with either a standard care packageor custom care package to match the needs of your siteconditions and application. The customer care packagesinclude calibration to known standards or calibration toyour target hydrocarbon, using sample analysis makingyour installation and start-up process trouble free. TheTD-120 is ideal for detection of oil leaks and spills forheat exchangers, boilers, and membrane systems as well asoptimization of water treatment systems.
With low detection limits and greatly extended detectionrange, the TD-120 provides the necessary tools andease of use to meet todays complex oil in water needs.
  • Internal table Interface for quick setup and calibration
  • New Auto-valve capabilities: temperature protection, fresh water flush and process isolation
  • Minimal Maintenance
  • Low cost of ownership- no reagents or instrument air needed for operation
  • OEM ooportunities
Request
Callback
Yes! I am Interested

Free Chlorine Sensor

Free Chlorine Sensor
  • Free Chlorine Sensor
  • Free Chlorine Sensor
  • Free Chlorine Sensor
  • Free Chlorine Sensor
  • Free Chlorine Sensor
  • Free Chlorine Sensor
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandPotence
ApplicationIndustrial Use
Response Time90 Sec
Measurement technologyReagent free Amperometric
Body MaterialPVC or ABS
Measurement Ranges0 / 2 / 5 / 10 / 20 ppm
Pressure Range15 psi
Output4- 20 mA
Ph Range5 to 9 pH

Description:

  • Principle : Reagent free Amperometric measurement
  • Long life with replacable membrane cap and refillable gel electrolyte.
  • Automatic temperature-compensated output.
  • Factory calibrated, No Zero calibration required.
Request
Callback
Yes! I am Interested

Online TSS Water Analyzer

Online TSS Water Analyzer
  • Online TSS Water Analyzer
  • Online TSS Water Analyzer
  • Online TSS Water Analyzer
  • Online TSS Water Analyzer
  • Online TSS Water Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Resolution0.01 to 1 NTU-mg/L
Accuracy< +- 5% of the reading
Measurement PrincipleR Light method Dispersed at 90 Degree (ISO 7027).
Max. Pressure5 Bar
Sensor CableStandard 7 Meter
Measurement Range0 to 4500 mg/L
Max. Refreshing Time< 1 second
Wetted Body MaterialPVC Body
Working Temp. Range0 to 50 DegreeC

Potence Controls PCTUS Turbidity / TSS System is an excellent choice for a wide range of applications like Urban wastewater treatment ; Sanitation network; Industrial effluent treatment; Surface water monitoring and Drinking water.
Turbidity Sensors are optical Sensors. The Sensor measurement principle is based on the IR Light method dispersed at 90° (ISO 7027). The measurement is carried out in the infrared range.
The sensor is calibrated in the factory, so there is no need to perform calibration during initial commissioning. All data regarding calibration, logs, users and measurments are processed directly in the sensor allowing for extremely reliable and traceable measurements.
Request
Callback
Yes! I am Interested

Oil In Water Analyzer

Oil In Water Analyzer
  • Oil In Water Analyzer
  • Oil In Water Analyzer
  • Oil In Water Analyzer
  • Oil In Water Analyzer
  • Oil In Water Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Common Target Oilsall oils listed for the TD-550 plus gas condensates, BTEX, gasoline, styrene, phenol, jet fuel, ke
Detection Range5 ppb to 5000 ppm (dependent on target oil)
CalibrationDirect and raw
Display Unitsppm, ppb, mg/l, ug/l, raw
ApprovalsCE
Data Logging and GraphingStores multiple calibrations and site locations Records each sample analyzed with time stamp, locati
PowerExternal power supply: 90-240 VAC and 6-8 hours on battery
Data OutputUSB and Micro SD card

Turner Designs Hydrocarbon Instruments proudly announces the all new dual-channel TD-560 Oil in Water Analyzer. In addition to the optical channel found in the TD-550, suitable for crude and other heavy oils, the TD-560 adds a second channel for detecting lighter hydrocarbons, such as BTEX, gas condensates, gasoline, jet fuel, kerosene, transformer oils, styrene and phenol. The TD-560 offers a greatly enhanced detection range (low ppb to 5000 ppm) over most oil in water analyzers.
Request
Callback
Yes! I am Interested

Online Manganese Analyzer

Online Manganese Analyzer
  • Online Manganese Analyzer
  • Online Manganese Analyzer
  • Online Manganese Analyzer
  • Online Manganese Analyzer
  • Online Manganese Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

ApplicationIndustrial Use
BrandSystea
Protection ClassIP55
Weight33 Kg
Dimension800x450x300 mm
Output Signal4-20 mA
Measuring Range0-2 ppm
Measuring Time13-15 minutes
Voltage12 V DC
Repeatabilitybetter than 4%

MICROMAC Manganese is a microprocessor controlled On Line analyzer specifically designed for automatic Manganese monitoring on several types of waters matrix.

Other Details:
  • Manganese monitoring on several types of waters matrix
  • Microprocessor controlled Analyzer
  • Rugged and reliable
  • Programmable photometer
  • Automatic calibration / validation / cleaning
  • Touch screen interface
  • Low reagent level alarm
  • Easy installation and operation
Request
Callback
Yes! I am Interested

Online Ammonia Analyzer

Online Ammonia Analyzer
  • Online Ammonia Analyzer
  • Online Ammonia Analyzer
  • Online Ammonia Analyzer
  • Online Ammonia Analyzer
  • Online Ammonia Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Automatic GradeAutomatic
MaterialMS
BrandSystea
Measurement ModeContinuous
Range- 0.050 to 1000 ppm NH3
Accuracybetter than 5%; SD% of 7 replicates at 20% of the full scale
Output Signal4-20mA
Resolution-0 to 10 ppm-0.001 ppm, -10 to 100 ppm - 0.01 ppm, -100 to 1000 ppm - 0.1 ppm
Protection TypeIP55
Sample Temperature10deg C - 30deg C
Measuring IntervalProgrammable
ColorimeterDual beam, Silicon detector
Measurement PrincipleGas-Sensing Ammonia Probe

It is a Microprocessorcontrolled On Line analyzer specifically designed forautomatic ammonia monitoring on several types ofwaters matrix.
Designed for industrial and Environmental On Lineapplications ensures the highest level of robustness inthe electronics, mechanics and hydraulics components.
  • Fully automatic operation
  • Long Autonomy, low maintenance, low operating cost.
  • Low reagents;consumption; short preparation time ; low disposable costs.
  • Easy operation; plug in analyzer, no special training is required
  • Electronics and hydraulics completely separated
  • Serial Interface for local or remote PC connection (option)
Request
Callback
Yes! I am Interested

Easychem Coli Online

Easychem Coli Online
  • Easychem Coli Online
  • Easychem Coli Online
  • Easychem Coli Online
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Usage/ApplicationIndustrial Use
Dimensions190 (H) x 80 (W) x 50 (D) cm
Power Supply12/24 VDC; External power supply from 110/220 VAC to 12/24 VDC included in the scope of delivery
Measuring TimeUp-to 15-18 hours for coliforms presence/absence detection
Operating Temperature10-35 Deg C
Measuring FrequencyTypically one sample/day
Sample DeliveryPressure: Atmospheric
Reagents ReplacementTypically every 20 days, up to 40 days
MountingStand alone industrial Cabinet
Power Absorption200 W
Weight100 kg
Measurement TypeFully Automated, direct read, online Discrete analyzer
Output signal and CommunicationsDigital outputs for alarm; RS232 output; RS485 optional
Protection TypeIP-55
HardwareIndustrial microcontroller PC panel with touch screen graphic display
MPN Measurement Time15-18 Hours
Environmental Temperature10-35C Reagents up to 25degree C

Direct Reading Dsicrete analyzer for Online detection of total Coliforms, Faecal coliforms and E.coli for potable, surface, waste and bathing water monitoring

Robust and reliable
Designed for industrial and environmental on-line applications, ensures the highest level of robustness in the electronics, mechanics and hydraulics components.

Feautres/ Benefits
  • Fully automatic operation
  • 20 days autonomy, one sample per day, with automatic detection of Total+ E. Coli and faecal coliforms or
  • 4o samples autonomy with automatic detection of total +E.coli or, alternatively,Faecal coliforms
  • USe of disposable 100ml bottles ensures water sample repesentatives and avoids any cross contamination
  • No need of long hydraulics washing using special cleaning solutions
  • Automatic generation of local and remote alarms through Ethernet or optional GSM/GPRS remote connection
  • Yearly Maintenance
Request
Callback
Yes! I am Interested

pH Industrial Electrode

pH Industrial Electrode
  • pH Industrial Electrode
  • pH Industrial Electrode
  • pH Industrial Electrode
  • pH Industrial Electrode
  • pH Industrial Electrode
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandPotence Controls
Usage/ApplicationIndustrial
Ph Range0 to 14
Accuracy+/- 0.2 pH
MaterialRyton Body (glass filled), Glass Process electrode
Flow Rate0-6.6 ft/sec( 0-2 m/sec)
Temp ElementPt100/ Pt1000
Pressure Limit0-100psig @ 100 DegreeC (0-6.9 bar @100 DegreeC)
Temp Limit0-105 DegreeC

Potence Controls PC Series combination pH/ORP sensors are designed for special applications. They can be mounted in a flow through Tee / Chamber or Immersed in Tanks or Vessels.
The reference cell is of double-Junction Porous Teflon design comes with a built-in solution Ground owing to which the performance of this sensor is enhanced. The body is made from chemically-resistant Ryton which is suitable for some of the most harsh applications. 
Request
Callback
Yes! I am Interested

Micromac Alkalinity Analyzer

Micromac Alkalinity Analyzer
  • Micromac Alkalinity Analyzer
  • Micromac Alkalinity Analyzer
  • Micromac Alkalinity Analyzer
  • Micromac Alkalinity Analyzer
  • Micromac Alkalinity Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Usage/ApplicationIndustrial Use
Dimension800x420x280 mm
Voltage12V DC
Output Signal4-20 mA
Weight33 kg
Measuring Time10-18 min
Protection TypeIP55
Frequency50/60 Hz

Easy To Install The analyzer is delivered after a long and successful series of factory tests ready for installation and setup; it is provided with complete set of spares for start up. To start monitoring is enough to connect reagents, sample line, waste line and power supply.

Automatic Calibration When the Calibration Time interval expires the analyzer performs a Calibration Cycle, storing and checking the new calibrant O. D. If new O.D. exceeds selected limits, an alarm contacts is closed.

Features And Benefit
  • Fully automatic operation
  • Long autonomy; low maintenance, low operating cost
  • Low reagents consumption; short preparation time; low disposable costs Easy operation; plug in analyzer, no special training is required
  • Electronics and hydraulics completely separated 
  • Serial interface for local o remote PC connection (option)
Request
Callback
Yes! I am Interested

Sulphate Analyzer Systems

Sulphate Analyzer Systems
  • Sulphate Analyzer Systems
  • Sulphate Analyzer Systems
  • Sulphate Analyzer Systems
  • Sulphate Analyzer Systems
  • Sulphate Analyzer Systems
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandSystea
Usage/ApplicationIndustrial Use
Automation GradeAutomatic
Range0-20 up to 200 ppm
Measuring PrincipleTurbidimetric,Barium Chloride
Outout4-20 mA
Protection ClassIP55

MICROMAC SULFATE is a microprocessor controlled On Line analyzer specifically designed for automatic sulfate monitoring on several types of water matrix. 

Other Details:

  • Industrial Waste Water
  • Microprocessor controlled Analyzer
  • Rugged and reliable
  • Programmable photometer
  • Automatic calibration / validation / cleaning
  • Free selectable measuring, cleaning and calibration intervals
  • Touch screen interface
  • Easy installation and operation
Request
Callback
Yes! I am Interested

Oil In Water Analyzer

Oil In Water Analyzer
  • Oil In Water Analyzer
  • Oil In Water Analyzer
  • Oil In Water Analyzer
  • Oil In Water Analyzer
  • Oil In Water Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

ApplicationIndustrial Use
BrandTrios
Power Supply12-24 VDC
Ambient Temperature5 - 55 DegreeC (0 - 40 DegreeC for given detection limits)
ParameterPAH,oil
Detection limits0.3ppb (enviroFlu-HC 500),0.5ppb (enviroFlu-HC 5000) in pure water
HousingPOM and stainless steel (1.4571) or titanium
Weight2.7 ( SS),1.9 kg (Titanium)
PrincipleUV fluorescence principle
Protection TypeIP68

Enviroflu-HC is the new generation of immersion sensors for measurement of oil-in-water. The used measuring principle  of UV Fluorescence is many times more sensitive than the conventionally used infrared scattering or absorption process. This makes it possible to determine even the slightest traces  of PAH's, such as in drinking water but also in cooling water condensates. Application areas include the petrochemical industry, leakage detection in cooling and wastewater streams as well as environmental monitoring. The devices enable both stationary use in shafts, flows or piping and mobile use through an optional hand-held measuring instrument. An innovative coating reduces fouling of the optical measuring window and minimizes the maintenance required. 
  • Principle : UV fluorescence
  • High sensitive submersible sensors
Request
Callback
Yes! I am Interested

Portable Oil In Water TD-550/ 560

Portable Oil In Water TD-550/ 560
  • Portable Oil In Water TD-550/ 560
  • Portable Oil In Water TD-550/ 560
  • Portable Oil In Water TD-550/ 560
  • Portable Oil In Water TD-550/ 560
  • Portable Oil In Water TD-550/ 560
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandTurner Design
Usage/ApplicationIndustrial
DisplayRemote
Model Name/NumberTD 550
Power Supply90-240 VAC and 6-8 hours on battery
Data OutputUSB and Micro SD card
Display Unitsppm,ppb,mg/l,ug/l,raw
Detection Range5 ppb to 5000 ppm

Turner Designs Hydrocarbon Instruments is proud to introduce the new standard in grab sample oil in water analysis - the TD 550 and TD-560. The TD-550, which features a greatly enhanced detection range (low ppb to 5000ppm), is well-suited for crude and other heavy oils. The TD-560 includes the same optical channel found in the TD-550 along with a second channel for detecting lighter hydrocarbons, such as BTEX, gas condensates, gasoline, jet fuel, kerosene, transformer oils, Styrene and phenol.

Description:

  • Introduces new standard in grab sample oil in water analysis
  • Advanced data logging and graphing capabilities
  • Large full-color touch screen interface
  • Approvals : CE
  • Results can be correlated to official lab methods such as USEPA 1664A and ISO 9377-1
Request
Callback
Yes! I am Interested

Online Nickel Analyzer

Online Nickel Analyzer
  • Online Nickel Analyzer
  • Online Nickel Analyzer
  • Online Nickel Analyzer
  • Online Nickel Analyzer
  • Online Nickel Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

ApplicationIndustrial Use
Voltage12 V DC
Sample Temperature10 DegreeC - 30 DegreeC
Measuring Time30- 35 minutes
Output Signal4-20 mA
Weight33 kg
Dimension800x450x300 mm
Protection ClassIP55
Repeatabilitybetter than 2%

Micromac Nickel is a microprocessor controlled Online Analyzer specifically designed for automatic Nickel Monitoring on several types of water matrices.

Other Details:

  • Nickel monitoring on several types of waters matrix
  • Microprocessor controlled Analyzer
  • Rugged and reliable
  • Programmable photometer
  • Automatic calibration / validation / cleaning
  • Touch screen interface
  • Low reagent level alarm
  • Easy installation and operation
Request
Callback
Yes! I am Interested

Automatic Silt Density Index Monitor

Automatic Silt Density Index Monitor
  • Automatic Silt Density Index Monitor
  • Automatic Silt Density Index Monitor
  • Automatic Silt Density Index Monitor
  • Automatic Silt Density Index Monitor
  • Automatic Silt Density Index Monitor
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Voltage120-240 VAC
Frequency50/60 Hz
Output4 isolated 4-20mA output
Communication PortRS 232 For Data Download
Sample Pressure70-1200 psi
Number Of Channel1,4
Analyzer MountingFlat Wall And Panel Surface

Monitoring the fouling tendency of RO Feedwater has long been a challenge. Usually fouling is not noticed until the RO membranes need cleaning, resulting in expensive downtime or worse yet membrane replacement. 

Numerous methods have used to measure the fouling tendencdy of feed waters, including turbidity, particle counting, and manual Silt Density Index (SDI) testing. It is difficult to correlate turbidity and particle counting to membrane fouling since they do not directly measure the fouling or plugging nature of the particles in suspension. Since the manual SDI test measures this plugging tendency, it has proven useful in indicating fouling tendencies.

Application: 
  • Large Desalination Projects
  • Filtered Water
  • RO Feed Water
  • Well Water
  • Clarified Effluent Samples
  • Sea water
Request
Callback
Yes! I am Interested

Online Arsenic Analyzer

Online Arsenic Analyzer
  • Online Arsenic Analyzer
  • Online Arsenic Analyzer
  • Online Arsenic Analyzer
  • Online Arsenic Analyzer
  • Online Arsenic Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Usage/ApplicationIndustrial Use
BrandSystea
Display TypeDigital
Dimensions800x450x300 mm
Measurement Range0-500 ppb As, higher ranges available on request
ProtectionIP55
Measurement IntervalProgrammable
Sample Temperature80 DegreeC
Measuring TimeAbout 60 minutes
Repeatabilitybetter than 2%
HardwarePC104 Industrial Standard, Integrated keyboard and graphics Display, RS 232 option
Weight33 Kg without reagents
Measurement TypeCycles
Output Signal4-20 mA

Its is a microprocessor controlled Online Analyzer specifically designed for automatic Arsensic monitoring on several types of Water Matrices.

Designed for industrial and Environmental Online applications ensures the highest level of robustness in the electronics, mechanics and hydraulics components. Complete separation between electronics and hydraulics plus a simple and robust LFA* hydraulics allows easy maintenance and long terms reliable operations.
  • Fully Automatic Operation
  • Long autonomy; low maintenance, low operating cost
  • Low Reagents consumption; short preparation time; low disposable costs
  • Easy operation; plug in analyzer, no special training is required.
  • Electronics and hydraulics completely separated.
  • Serial Interface for local o remote PC connection (Option)
Request
Callback
Yes! I am Interested

pH Conductivity Controller

pH Conductivity Controller
  • pH Conductivity Controller
  • pH Conductivity Controller
  • pH Conductivity Controller
  • pH Conductivity Controller
  • pH Conductivity Controller
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandPotence
Analog OutputTwo Nos. 4-20 mA isolated current outputs,max 600 Ohm
DisplayGraphic LCD with Backlit display
Voltage100 - 270 V AC
Frequency50/60 Hz
MountingWall ; Pipe ; Panel
InterfaceModbus RS 485 Output
EnclosureIP 65
Display Dimension60 x 30 mm

Potence Controls PC2000 series DUAL CHANNEL Analyzers for pH/ORP/Conductivity/TDS measurements incorporate state of the art technology to provide flexible and reliable solutions to the customer for their Process Monitoring and Control needs. Any two of the measurements from pH / Redox (ORP) / Conductivity / Total Dissolved Solids (TDS) can be freely selected for use with the PC2000 Analyzer via software, thus reducing the need of individual dedicated controllers; the PC2000 can be picked up off the shelf and can be used for any 2 of the above measurements.
Request
Callback
Yes! I am Interested

Online Chromium Analyzer

Online Chromium Analyzer
  • Online Chromium Analyzer
  • Online Chromium Analyzer
  • Online Chromium Analyzer
  • Online Chromium Analyzer
  • Online Chromium Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Voltage12/24 V DC
Dimension800x450x300 mm
Weight33 Kg
Output Signal4-20 mA
Sample Temperature0 DegreeC - 30 DegreeC
Repeatabilitybetter than 2%
Measuring TimeAbout 20-23 minutes

Micromac Chromium is a microprocessor controlled Online Analyzer specifically designed for automatic Chromium 6+ monitoring on several types of water matrices.

Description:

  • Fully automatic operation
  • Long autonomy; low maintenance, low operating cost
  • Low reagents consumption; short preparation time; low disposable costs
  • Easy operation; plug in analyzer, no special training is required
  • Electronics and hydraulics completely separated
  • Serial interface for local or remote PC connection (option)
Request
Callback
Yes! I am Interested

Online Copper Analyzer

Online Copper Analyzer
  • Online Copper Analyzer
  • Online Copper Analyzer
  • Online Copper Analyzer
  • Online Copper Analyzer
  • Online Copper Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

ApplicationIndustrial Use
BrandSystea
Dimension800x450x300 mm
Voltage12 V DC
Output Signal4-20 mA
Measuring Time33 minutes
Weight33 kg
ProtectionIP55
Sample Temperature10 DegreeC - 30 DegreeC

Micromac Copper is a microprocessor controlled On Line analyzer specifically designed for automatic Copper monitoring on several types of water matrix. 

Other Details:

  • Copper monitoring on several types of waters matrix
  • Microprocessor controlled Analyzer
  • Rugged and reliable
  • Programmable photometer
  • Automatic calibration / validation / cleaning
  • Touch screen interface
  • Low reagent level alarm
  • Easy installation and operation
Request
Callback
Yes! I am Interested

Online Sulfide Analyzer

Online Sulfide Analyzer
  • Online Sulfide Analyzer
  • Online Sulfide Analyzer
  • Online Sulfide Analyzer
  • Online Sulfide Analyzer
  • Online Sulfide Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

ApplicationIndustrial Use
Automation GradeAutomatic
BrandSystea
Range0-2 / 100 ppm
Measuring Time15 minutes
Weight33 kg
Output Signal4-20 mA
Measuring PrincipleColorimetric
Protection RateIP55
Dimension800x450x300 mm

Micromac Sulfide is a microprocessor controlled Online Analyzer specifically designed for automatic sulfide monitoring on several types of waters matrix.

Other Details:

  • Industrial Waste Water
  • Microprocessor controlled Analyzer
  • Rugged and reliable
  • Programmable photometer
  • Automatic calibration / validation / cleaning
  • Free selectable measuring, cleaning and calibration intervals
  • Touch screen interface
  • Easy installation and operation
Request
Callback
Yes! I am Interested

Online Iron Analyzer

Online Iron Analyzer
  • Online Iron Analyzer
  • Online Iron Analyzer
  • Online Iron Analyzer
  • Online Iron Analyzer
  • Online Iron Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandSystea
Weight33 Kg
Dimension800x450x300 mm
ProtectionIP55
Environmental Temperature10 DegC - 40 DegC
Repeatabilitybetter than 2%
Measuring Time7-10 min

MICROMAC IRON is a microprocessor controlled On Line analyzer specifically designed for automatic iron monitoring on several types of waters matrix.

Other Details:

  • Iron monitoring on several types of waters matrix
  • Microprocessor controlled Analyzer
  • Rugged and reliable
  • Programmable photometer
  • Automatic calibration / validation / cleaning
  • Touch screen interface
  • Low reagent level alarm
  • Easy installation and operation
Request
Callback
Yes! I am Interested

TSS Water Analyzer

TSS Water Analyzer
  • TSS Water Analyzer
  • TSS Water Analyzer
  • TSS Water Analyzer
  • TSS Water Analyzer
  • TSS Water Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Usage/ApplicationIndustrial Use
Resolution0.01 to 1 NTU-mg/L
Accuracy< +- 5% of the reading
Wetted Body MaterialPVC Body
Sensor CableStandard 7 Meter
Max. Pressure5 Bar
Measurement PrincipleIR Light Method dispersed at 90 Degree (ISO 7027)
Measurement Range0 to 4500 mg/L
Max. Refreshing Time< 1 second
Working Temp. Range0 to 50 DegreeC

Potence Controls PCTUS Turbidity / TSS System is an excellent choice for a wide range of applications like Urban wastewater treatment ; Sanitation network; Industrial effluent treatment; Surface water monitoring and Drinking water.
Turbidity sensors are optical sensors. The sensor measurement principle is based on the IR light method dispersed at 90° (ISO 7027). The measurement is carried out in the Infrared range.
The sensor is calibrated in the factory, so there is no need to perform calibration during initial commissioning. All data regarding calibration, logs, users and measurements are processed directly in the sensor allowing for extremely reliable and traceable measurements.
Request
Callback
Yes! I am Interested

Online Cyanide Analyzer

Online Cyanide Analyzer
  • Online Cyanide Analyzer
  • Online Cyanide Analyzer
  • Online Cyanide Analyzer
  • Online Cyanide Analyzer
  • Online Cyanide Analyzer
  • Online Cyanide Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

ApplicationIndustrial Use
Voltage12 VDC
Dimension800x450x300 mm
Output Signal4-20 mA
Sample Temperature10 DegreeC - 30 DegreeC
Measuring TimeAbout 8-10 Minute
IP RatingIP55

Micromac Cyanide is a microprocessor controlled Online Analyzer specifically designed for automatic Cyanide monitoring on several types of water matrices.

Other Details:

  • Cyanide monitoring on several types of waters matrix
  • Microprocessor controlled Analyzer
  • Rugged and reliable
  • Programmable photometer
  • Automatic calibration / validation / cleaning
  • Touch screen interface
  • Low reagent level alarm
  • Easy installation and operation
Request
Callback
Yes! I am Interested

Online Silica Analyzer

Online Silica Analyzer
  • Online Silica Analyzer
  • Online Silica Analyzer
  • Online Silica Analyzer
  • Online Silica Analyzer
  • Online Silica Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Voltage120-240 VAC
Frequency50/60 Hz
Weight38 kg
Space requirement for Mounting1050 x 550 x 500 mm
Determination Limit0.5 ppb
Dimensions850 x 450 x 250 mm
Protective systemIP-65

The determination of dissolved silicic acid (ortho-silicate) in the watersteam cycle is of great importance for the operation and plant safety in power plants. In addition to the determination of ortho-silicate in the live steam in order to avoid deposits or crystallisation inside the turbine, it is possible to detect an aperture in the anion filter or mixed bed exchanger.

Request
Callback
Yes! I am Interested

High Range Chloride Analyzer

High Range Chloride Analyzer
  • High Range Chloride Analyzer
  • High Range Chloride Analyzer
  • High Range Chloride Analyzer
  • High Range Chloride Analyzer
  • High Range Chloride Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

ApplicationIndustrial Use
Weight33 kg
Sample and Waste DeliveryPressure Free
Measuring TimeAbout 10 Minute
ProtectionIP55
Dimension800x450x300 mm
Protection RateIP55
Output Signal4-20 mA
Measuring PrincipleColorimetric, Mercury (II) Thiocyanate
Repeatabilitybetter than 2%
Automation GradeAutomatic
Sample Temperature10 DegreeC - 30 DegreeC
Detection Limittypically better than 2% of full scale, calculated as for EPA
Measurement Range0-100 up to 500mg/L as Cl- ; other ranges available on request

It is a microprocessorcontrolled On Line analyzer specifically designed forautomatic Chloride monitoring on several types of watermatrices.
Designed for industrial and Environmental On Lineapplications ensures the highest level of robustness inthe electronics, mechanics and hydraulics components.
  • Fully Automatic operation
  • Long Autonomy; low maintenance, low operating cost low power consumption
  • Low Reagents consumption; short preparation time, low disposable Costs
  • Easy operation; plug in analyzer no special training is required
  • Serial Interface for local or remote PC connection (option)
Request
Callback


Additional Information:

  • Item Code: CL402
Yes! I am Interested

Online Sodium Analyzer

Online Sodium Analyzer
  • Online Sodium Analyzer
  • Online Sodium Analyzer
  • Online Sodium Analyzer
  • Online Sodium Analyzer
  • Online Sodium Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

ApplicationIndustrial Use
BrandDr. Thiedig
DisplayGraphic
Alarm outputTwo relays
Weight30.0 kg
Analog output4 to 20 mA
Dimensions850 x 450 x 250 mm
Space requirement for Mounting850 x 550 x 500 mm
Voltage100 to 240 VAC
Frequency50/60 Hz
Range0.1 to 2000 ppb

The determination of sodium in low concentrations in the water-steam cycle is of great importance in power plants. On the one hand, this is due to the fact that the signifi cance of sodium in corrosion processes has become more and more recognized over the last few years. On the other hand, this measurement procedure enables a fast monitoring of a leakage for instance in the condenser or the aperture in a cation fi lter or a mixed bed fi lter. Not least for that reason, the sodium measurement has become increasingly important with revising the VGB-guidelines (S-006 / S-010)

Description:

  • Measuring Principle : Ion Selective
  • Automatic three-point calibration, adjustable time interval
  • Control and monitoring of the adjustable pH value
  • Built-in sequencer for up to 6 sample channels
  • Additional connection for the measurement of a laboratory sample
Request
Callback
Yes! I am Interested

Online Aluminum Analyzer

Online Aluminum Analyzer
  • Online Aluminum Analyzer
  • Online Aluminum Analyzer
  • Online Aluminum Analyzer
  • Online Aluminum Analyzer
  • Online Aluminum Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

ApplicationIndustrial Use
Weight33 kg
Protection ClassIP55
Voltage12 V DC
Sample Temperature10 DegreeC - 30 DegreeC
Measuring Time10 Min
Protection RateIP55
Dimension800x450x300 mm

Micromac Aluminum is a microprocessor controlled Online analyzer specifically designed for automatic aluminum monitoring on several types of waters matrix.

Features:
  • Fully Automatic operation
  • Long autonomy; low maintenance, low operating cost.
  • Low reagents consumption, short preparation time; low disposable costs
  • Easy operation; plug in analyzer, no special training is required
  • Electronics and hydraulics completely separated
  • Serial interface for local or remote PC connection (option)
Request
Callback
Yes! I am Interested

Hydrazine Analyzer

Hydrazine Analyzer
  • Hydrazine Analyzer
  • Hydrazine Analyzer
  • Hydrazine Analyzer
  • Hydrazine Analyzer
  • Hydrazine Analyzer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

ApplicationIndustrial Use
Dimensions580 x 335 x 140 mm
IP RatingIP 65
Frequency50/60 Hz
Sample Pressure0-8 Bar, Pressure peaks up to 16 bar
Ambient Temperature0-40 Deg C
RepeatabilityLess Than 1%
Weight8.0 kg
Voltage100-240 VAC

The Digox 6.1 is an instrument to measure the concentration of dissolved hydrazine in high purity water by means of amperometry. The Hydrazine is oxidised at a gold electrode, which is in direct contact with the water. Therefore short response times and highest accuracies are ensured.
One of the feature of the Digox 6.1 is its robust sensor which is low maintenance. Due to the modular construction of the instrument, the sensor is easily accessible if it needs to be cleansed or serviced.

Advantages 

  • High accuracy, short response time, no drift of the signal
  • Robust sensor, low maintenance
Request
Callback
Yes! I am Interested
X

Explore More Products

View All Products




Reach Us
Prashant Thakkar (Director)
Potence Controls Pvt. Ltd.
G-416a, Kailas Industrial Complex, 90 Feet D.p. Road, Parksite Vikhroliwest, Mumbai Suburban
Mumbai - 400079, Maharashtra, India
Get Directions


Call Us


Send E-mail