Pioneers in the industry, we offer moisture measurement instrument, gas moisture analyzers, gas moisture measurement, online moisture sensor and dew point sensor from India.
Get Latest Price
| Ranges | -148 DegreeF to +68 DegreeF (-100 DegreeC to +20 DegreeC) Dew Point |
| Accuracy | +-3.6 DegreeF (+-2 DegreeC) Dew Point |
| Response time | 90% of reading (T95) less than 5 minutes (dry to wet) |
| Signal outputs | 4-20mA (2 wire) |
| Operating Humidity | 0-100% RH |
| Operating Temperature | -40 DegreeF to +140 DegreeF (-40 DegreeC to +60 DegreeC) |
| Operating Pressure | 450 Barg / 6500 psi / 45 mPa |
| Flow Rate | 0.5 to 7 NL/min |
Get Latest Price
| Response Time | 90% of reading (T95) less than 5 minutes (dry to wet) |
| Accuracy | +-2 DegreeC (+-3.6 DegreeF) Dew Point |
| Operating Temperature | -40 DegreeC to +60 DegreeC (-40 DegreeF to +140 DegreeF) |
| Ranges | -100 DegreeC to +20 DegreeC (-148 DegreeF to +68 DegreeF) Dew Point |
| Signal outputs | 4-20mA (2 wire) |
| Operating Humidity | 0-100% RH |
Get Latest Price
| Response Time | 90% of reading (T95) less than 5 minutes (dry to wet) |
| Flow Rate | 0.5 to 7 NL/min |
| Operating Pressure | 450 Barg / 6500 psi / 45 mPa |
| Accuracy | +-2 DegreeC (+-3.6 DegreeF) Dew Point |
| Ranges | -100 DegreeC to +20 DegreeC (-148 DegreeF to +68 DegreeF) Dew Point |
| Signal outputs | 4-20mA (2 wire) |
| Operating Humidity | 0-100% RH |
| Operating Temperature | -40 DegreeC to +60 DegreeC (-40 DegreeF to +140 DegreeF) |
Get Latest Price
| Response Time | 90% of reading (T95) less than 5 minutes (dry to wet) |
| Accuracy | +-2 DegreeC (+-3.6 DegreeF) Dew Point |
| Technology | Aluminium oxide |
| Degree Of Protection | IP66 (NEMA 4) |
| Measurement | -100 DegreeC to +20 DegreeC (-148 DegreeF to 68 DegreeF) dew point |
| Application | Industrial Gas, Intrinsically Safe |
Get Latest Price
| Accuracy | +- 2% of scale* |
| Ranges | Dependent on selected gas mix. Adjustable, auto-ranging. Typical: 0-1000ppm (H2 in N2) 98-100% (O2 i |
| Resolution | 0.5% or better |
| Response Time | 90% of reading in 20 seconds |
| Calibration Range | 0-100% of selected measure gas. Automatic timed calibration as standard. Auto zero. |
| Alarms | Two adjustable alarms with volt-free, change-over contacts Fully configurable over complete range. C |
| Analogue Outputs | 0-10V, 4-20mA (both isolated). Max loop resistance 500 Ohms |
| Serial Interface | Allows connection to a computer |
| Sample Inlet Pressure | 1.0 to 7.0 Barg |
| Sample Flow Rate | Internally controlled (max 250ml/min) |
| Sample temperature | -10 to 40 DegreeC |
PRASHANT JETHABHAI THAKKAR (Director)
Potence Controls Pvt. Ltd.
G-416a, Kailas Industrial Complex, 90 Feet D.P. Road, Parksite Vikhroli West
Mumbai - 400079, Maharashtra, India