Water Quality Analyser

Leading Manufacturer of dissolved oxygen sensor, pc 200 dissolved oxygen analyzer, e coli online analyser, pc con100 loop-powered contacting conductivity transmitter, contacting conductivity tds and resistivity sensors and ph sensor from Mumbai.

Dissolved Oxygen Sensor

Dissolved Oxygen Sensor
  • Dissolved Oxygen Sensor
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Operating Temperature- 5 to 50 Degree C
Measuring Range0-20 ppm,0-200% Saturation
Response TimeT90 < 40 Seconds
ApplicationIndustrial
BrandPotence
Accuracy+-0.1 ppm below 1 ppm; +-0.2 ppm above 1 ppm; +-1% of reading
Body MaterialPVC Or SS Body
CommunicationModbus RS 485
Output Signal4-20 mA
Sensor Cable6 m (Optional Cable Length Available Up To 100 Meters)

Features

Potence Controls Optical Dissolved Oxygen sensors measure Dissolved Oxygen with great accuracy in waste water plants.They can connect to any existing measurement systems that accept a 4-20 mA input. This feature reduces the loop cost drastically as you can use any off the shelf Indicator and configure to measure Dissolved Oxygen.

Optical technology is based on the proven method wherein Oxygen concentration is determined by the luminescent quenching of a dye embedded on the sensor surface. Unlike polarographic or galvanic sensor this Optical sensors does not require filling solutions nor a warm up time.Connect it to the indicator and it is up and running within no time

Benefit:

  • Affordable as you do not have to rely on any specific controllers.
  • 4-20mA output from sensor enables seamless connectivity to field transmitters or PLC/DCS.
  • Replaceable sensor cap. No calibration or replacement sensor cap for at least 1 year in most applications.
  • Saltwater compensation. Sample flow not necessary for measurement accuracy.
  • The sensor come with a choice of PVC body or SS 316 body version.
  • Sensor cable length up to 100 meters allow flexibility in the field
Request
Callback
Yes! I am Interested

PC 200 Dissolved Oxygen Analyzer

PC 200 Dissolved Oxygen Analyzer
  • PC 200 Dissolved Oxygen Analyzer
Ask For Price
Product Price :Get Latest Price

Product Details:

ApplicationIndustrial Use
Response Time90% value in less than 60 seconds
Weight1.1 kg
Working Temperature Range0 to 50 Deg C
Maximum Pressure5 Bar
Power Requirement110 VAC / 230 VAC ; +- 10% ; 50 / 60 Hz
Enclosure MountingWall,Panel

Features:
  • Potence Controls PCODOS Optical Dissolved Oxygen System is an excellent choice for an accurate measure in all situation with wide range of applications like Urban wastewater treatment; Industrial effluent treatment ;Surface water monitoring ; Sea water monitoring, Fish farming, Aquarium and Drinking water. The Optical Dissolved Oxygen sensor is based on Luminescent optical technology.
  • Without calibration requirements with ultra-low power technology, the Optical Dissolved Oxygen sensor meets the demands of field works. The smart Optical Dissolved Oxygen sensor stores calibration and history data within the sensor. This allows you a plug and play system.

Benefit:
  • Optical Technology without calibration.
  • No Drift, Reduced Maintenance
  • Stainless Steel (316L) or Titanium Body for Corrosive Applications
  • Controller with two digital sensor inputs.
  • Backlit Display
  • Password Protected Access
  • Robust and Waterproof (IP 68) PCODOS Optical Dissolved Oxygen System Features & Benefits
  • Real time clock with Battery backup
Request
Callback
Yes! I am Interested

E Coli Online Analyser

E Coli Online Analyser
  • E Coli Online Analyser
Ask For Price
Product Price :Get Latest Price

Product Details:

Weight100 kg
Dimension190 (H) x 80 (W) x 50 (D) cm
Measuring TimeUp to 15-18 hours for coli forms presence/absence detection
Operating InterfaceColour graphic touch-screen 15" display
Number Of Test Tube2 x 28, on Automatic Rotating Circular Trays
Protection RateIP 55
Power Absorption200 W

Description:

  • Measuring Principle : Colorimetric (total & faecal coliforms) and fluorimetric (E. coli)
  • Measuring Frequency : Up to two samples / day (3 parameters), four samples / day (single parameter)
  • Output & Interface : Digital outputs for alarm; RS232 output; RS485 optional
  • Automatic generation of local and remote alarms through Ethernet or optional GSM/GPRS remote connection.

 

Request
Callback
Yes! I am Interested

PC CON100 Loop-Powered Contacting Conductivity Transmitter

PC CON100 Loop-Powered Contacting Conductivity Transmitter
  • PC CON100 Loop-Powered Contacting Conductivity Transmitter
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Usage/ApplicationIndustrial Use
BrandPotence
Accuracy+-1%
Dimension96 x 96 x 66 mm
Weight210 g
Voltage12-24 V DC
Temperature Accuracy+-0.5 Degree C (0.9 Degree F)
Temperature Resolution0.1 Degree C
MountingWall Mounting
DisplayDual Display Custom LCD
Sensor Pt1003 Wire/2 Wire

Conductivity System
Request
Callback
Yes! I am Interested

Contacting Conductivity TDS And Resistivity Sensors

Contacting Conductivity TDS And Resistivity Sensors
  • Contacting Conductivity TDS And Resistivity Sensors
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandPotence
Usage/ApplicationLaboratory
Material316 Stainless Steel,Teflon Insulator
Cell ConstantAvailable 0.01,0.1,1.0,10
Temperature ElementPT100 or PT1000
MeasurementsConductivity / TDS
Sensor TypeContacting type sensor,2 electrodes
Conductivity Range0-200,000 microSiemens/cm
Standard Cable Length20 Feet (6 Meter)

Request
Callback
Yes! I am Interested

pH Sensor

pH Sensor
  • pH Sensor
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandPotence
MaterialTeflon Body(glass filled)
Cable Length15 Feet
Process Connection3/4 Inch NPT (M)
Temperature ElementPt-100 / Pt-1000
pH Range0 - 14 pH

Request
Callback
Yes! I am Interested

COD Analyzer

COD Analyzer
  • COD Analyzer
Ask For Price
Product Price :Get Latest Price

Product Details:

Usage/ApplicationIndustrial
BrandPotence
MaterialMS
ShapeRectangular
Automation TypeAutomatic
PhaseThree Phase
Operating Voltage220 V
Frequency50 Hz